PC insulation board is commonly used in electrical assembly, industrial control equipment, new energy equipment insulation protection material. It has the advantages of high thermal insulation, good toughness and convenient processing, and has become the preferred material to replace traditional electrowood and epoxy boards. However, in the actual assembly and use process, many workers in selection, identification, assembly irregularities and other errors, resulting in cracks, yellowing, insulation failure, premature aging and other malfunctions, resulting in leakages, short circuit, equipment failure and other safety hazards. Combining with practical experience, this paper combs out the causes and choices of common faults of PC insulation boards, and the main points of avoiding installing pitfalls, and provides a practical reference for electrical construction and equipment maintenance.
First of all, combing the high frequency fault and core reason of the electrically equipped PC insulation boards. The most common faults are plate cracking and brittleness, which is not the material itself, but due to poor selection and assembly. Using inferior quality sheet metal mixed with recycled material, its toughness is insufficient, due to long-term vibration and temperature difference of equipment, can quickly produce fine lines and cracks; Tightening screws, forced alignment and bending, hole stress concentration, etc., can also lead to late cracking and failure of sheet metal. Secondly, the insulation performance decreased, manifesting slight leakage, leakage, high-pressure breakdown, mainly due to the presence of impurities in the plate, inner hole, or long-term moisture, oil contamination, chemical agent corrosion, etc., destroyed the surface insulation structure.
Yellowing, aging, deformation and softening of plates are also common faults. The equipment operates at high temperature for a long time, and ordinary non modified PC boards has poor high temperature resistance. Continuous heating accelerates oxidation and yellowing, and materials become brittle. Outdoor equipment and outdoor industrial control devices that use panels without an UV-resistant coating can become powdery and deformed due to prolonged exposure to UV light, leaving them completely unprotected. In addition, after processing, some plates appeared edge damage and cracks, mainly due to passive cutting tools, drilling speed too fast, violent processing caused hidden danger. It is easy to spread and crack in the later stage, which affects the safe operation of equipment.
Misconceptions of type selection is the core cause of all kinds of faults and the most important point to avoid in electrical assembly. The first major misconception is "look at the price, not the material." Many people opt for cheap recycled PC panels to reduce costs. The thickness of these plates is not uniform, many impurities, poor toughness, insulation parameters not up to standard. While they may seem to save money, frequent failures later in life actually increase maintenance costs. Legitimate industrial electrical panels must use brand new native PC materials that are compact, porous, and have insulation, toughness, and flame retardant properties that meet electrical standards.
The second most major misconception is ``image update ''. Many in the industry mistakenly believe that all PC insulation boards have the same performance and are randomly mixed. In fact, there is a great difference between ordinary decorative PC panels and industrial electricity-specific insulation boards. Ordinary sheet metal has no flame retardant, anti-aging modification effect and is only suitable for decoration scenes. They cannot withstand the high temperature, high voltage and vibration conditions of electrical equipment and are prone to safety hazards after installation. Electrical assemblies shall be marked * * Flame-retardant Insulation Modified Industrial Class PC Plates * * to eliminate substitution and mixing of common plates.
The third major mistake is"ignoring thickness and process adaptation." The thickness of the plate directly determines its compressive and impact resistance plate. Different conditions, such as cabinet partition, high pressure isolation, equipment protection, etc., the thickness of the plate requirements are different. Insufficient thickness can lead to deformation and inadequate protection under stress. At the same time, when selecting the plate, the the flatness plate, no scratches, no bubbles, no concave need to be verified. Poor quality plates are prone to safety hazards after processing and assembly. In addition, 12V, 24V low voltage equipment and high voltage distribution equipment need to be matched with appropriate insulation, pressure class board, not uniform mixing.
Finally, master assembly, maintenance, pit avoidance and other technologies, completely eliminate the hidden trouble. Sharp knives should be used and cut and drill at constant speeds to avoid microcracks caused by intense processing. Screws should be tightened properly during assembly and gaskets installed to disperse stress and prevent plates from being forced to bend. Exposure to organic solvents and corrosive cleaning agents should be avoided during use, and oil and dust should be cleaned regularly. At the same time, according to the choice of usage environment, high temperature, outdoor, humid working conditions should be preferred to use the temperature-resistant, uv, moisture resistant modified plate. In conclusion, in order to give full play to the protection advantages of PC insulation boards, avoid all kinds of faults, and ensure the long-term safe and stable operation of electrical equipment, we must achieve precision selection, assembly specification and maintenance science.
Nov 15, 2026
PC Insulation Board Faults And Selection Avoidance, Practical Guide To Electrical Assembling